IEC/EN 60947-5-1; EN 1088;
EN 50014; EN 50018;
EN 50019; EN 50281-1-1
Enclosure aluminium die casting, enamelled
Cover steel, enamelled
Actuator/locking bolt metal zinc/aluminium
Switch insert Ex 95
Protection class IP 67 according to EN 60529
Contact material silver
Switching system slow action, NC contact with positive break
Switching elements change-over contact with double break Zb, galvanically separated contact bridges
Termination M3 screw clamps
Cable section max. 2.5 mm2 (incl. conductor ferrules)
Cable entries 2 x M20 x 1.5 for cable section 5 … 9 mm
Cable length -
Uimp 4 kV
Ui 250 V
Ithe 6 A
Ie/Ue 6 A/250 VAC; 40 mA/24 VDC
Utilisation category AC-15
Max. fuse rating 6 A gL/gG D-fuse
Us 24 VDC
Magnet 100 % ED
Unlocking 100 % ED
Power consumption max. 12 W
Ambient temperature –20 °C … +55 °C
Mechanical life > 1 million operations
Holding force F max. 3500 N
Holding force of integrated ball catch 120 - 400 N, adjustable
Ex certification II 2G EEx dem IIC T6,
II 2D IP67 T80°C
Approvals DMT 02 ATEX E 255 X
无锡市库勒自动化科技有限公司